Journeyman Ductable Oil Indirect-Fired Heater
Owner’s Manual • Journeyman
17
6. Head assembly
7. Electrode assembly
8. Nozzle line assembly
9. Nozzle
WARNING
Electrode Specifications
■ Failure to properly maintain these specifications
could cause ignition malfunction, puff-back of hot
gases, heavy smoke, asphyxiation, explosion
and fire hazard.
Adjust the electrode gap and position in relation to the
nozzle to the following specifications.
P 1/4”
Q 1/8”
R 5/32”
6
9
7
8
High Limit Switches
This heater is equipped with two auto reset high limit
switches. These are normal closed high limit switches and are
non-adjustable. They are located inside a metal enclosure on
the side of the heater.
NOTE: The rear high limit switch is rated for 125°F and the
front high limit switch is rated for 190°F.
Both high limit switches should be tested a minimum of once
per year when the heater is given a thorough cleaning.
1. Remove the high limit switch.
2. Apply a small flame only to the sensing portion on the back
of the switch.
WARNING
Fire Hazard
■ Do not operate the heater with either of the high
limit switches bypassed.
■ Operating the heater with a bypassed high limit
switch may lead to overheating, possibly
resulting in a fire, with subsequent damage to
the heater or property damage.
REAR LIMIT
SWITCH
FAN
SWITCH
FRONT
LIMIT SWITCH
TERMINAL
MOUNTING
LEG
SENSING SURFACE
Summary of Contents for Journeyman
Page 26: ...Journeyman Ductable Oil Indirect Fired Heater www lbwhite com Owner s Manual Journeyman 26...
Page 27: ...Journeyman Ductable Oil Indirect Fired Heater Owner s Manual Journeyman 27...
Page 78: ...Journeyman Fournaise huile canalisable chauffage Manuel du propri taire Journeyman 25...
Page 80: ...Journeyman Fournaise huile canalisable chauffage Manuel du propri taire Journeyman 27...