2L6/2N6/2N5/2N4
1-4-71
1020
Lift motor 2 error
After cassette 2 is inserted, lift
sensor 2 does not turn on
within 12 s. This error is
detected 5 times successively.
The lock signal of the motor is
detected continuously for 1 s.
This error is detected 5 times
successively.
Cassette lift base
elevating
mechanism
Check that the cassette base can be
manipulated smoothly, if not, repair or
replace.
Lift motor 2
1. Check that the cassette base has been
ascended.
2. Check the drive gear can rotate or they
are not unusually loaded and, if
necessary, replace.
3. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Lift motor 2 and Feed PWB 2 (YC3)
Feed PWB 2 (YC1) and Engine PWB
(YC4)
4. If the wiring is disconnected, shorted or
grounded, replace the wiring.
5. Replace the lift motor 2.
Lift sensor 2
1. Check that the sensor is correctly
positioned.
2. Confirm that the wiring connector is
firmly connected and, if necessary,
connect the connector all the way in.
Lift sensor 2 and Feed PWB 2 (YC8)
Feed PWB 2 (YC1) and Engine PWB
(YC4)
3. If the wiring is disconnected, shorted or
grounded, replace the wiring.
4. Replace the lift sensor2.
Feed PWB 2
Replace the Feed PWB 2.
Engine PWB
1. Check the engine software and upgrade
to the latest, if necessary.
2. Replace the engine PWB (see page 1-5-
80).
Code
Contents
Related parts
Check procedures/
corrective measures
Summary of Contents for TASKalfa 3051ci
Page 5: ...2L6 2N6 2N5 2N4 1 4 4 Machine Option2 Figure 1 4 4 Paper jam location Matchine Option2 ...
Page 201: ...2L6 2N6 2N5 2N4 5 1 4 200 ...
Page 202: ...2L6 2N6 2N5 2N4 5 1 4 201 ...
Page 203: ...2L6 2N6 2N5 2N4 5 1 4 202 ...
Page 204: ...2L6 2N6 2N5 2N4 5 1 4 203 ...
Page 257: ...2L6 2N6 2N5 2N4 5 1 4 256 16 Grainy image See page1 4 272 ...