2H9
1-3-41
U425
Setting the target
Description
Enters the lab values that is indicated on the back of the chart (P/N: 302FZ56990) used for adjustment.
Purpose
Performs data input in order to correct for differences in originals during automatic adjustment.
Method
1. Press the start key.
2. Select the item to be set.
3. Select the item to be set.
4. Enters the value that is indicated on the back of the chart using the cursor left/right keys.
5. Press the start key. The value is set.
6. To return to the screen for selecting an item, press the stop key.
Setting: [ADJUST ORIGINAL]
1. Measure the distance from the left edge to the black belt (a) of the original at A, B and C.
Measurement procedure
1) Measure the distance from the edge to the black belt (a) of the original at A (35 mm from the leading
edge), B (110 mm from the leading edge) and C (185 mm from the leading edge), respectively.
2) Apply the following formula for the values obtained: ((A + C) / 2 + B) / 2
2. Enter the values solved using the cursor left/right keys in [MAIN].
3. Press the start key. The value is set.
4. Measure the distance from the leading edge to the black belt (b) of the original at D, E and F.
Measurement procedure
1) Measure the length from the edge to the black belt (b) of the original at D (30 mm from the left edge),
E (148.5 mm from the left edge) and F (267 mm from the left edge), respectively.
2) Apply the following formula for the values obtained: ((D + F) / 2 + E) / 2
5. Enter the values solved using the cursor left/right keys in [SUB LEAD].
6. Press the start key. The value is set.
7. Measure the length (G) from the leading edge of the black belt (b) to the bottom of the N475 patch of the
original.
8. Enter the measured value using the cursor left/right keys in [SUB TAIL].
9. Press the start key. The value is set.
10. To return to the screen for selecting an item, press the stop key.
Maintenance
item No.
Description
Display
Description
N875
Setting the N875 patch for the original for adjustment
N475
Setting the N475 patch for the original for adjustment
N125
Setting the N125 patch for the original for adjustment
CYAN
Setting the cyan patch for the original for adjustment
MAGENTA
Setting the magenta patch for the original for adjustment
YELLOW
Setting the yellow patch for the original for adjustment
RED
Setting the red patch for the original for adjustment
GREEN
Setting the green patch for the original for adjustment
BLUE
Setting the blue patch for the original for adjustment
ADJUST ORIGINAL
Setting the main and auxiliary scanning directions
Display
Description
Setting range
L
Setting the L value
0.0 to 100.0
a
Setting the a value
-200.0 to 200.0
b
Setting the b value
-200.0 to 200.0
Summary of Contents for KM-2810
Page 1: ...SERVICE MANUAL Published in May 2009 2H9SM060 First Edition KM 2810 ...
Page 3: ...Revision history Revision Date Replaced pages Remarks ...
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 18: ...2H9 1 1 6 This page is intentionally left blank ...
Page 22: ...2H9 1 2 4 5 Remove nine tapes Figure 1 2 5 Tape Tapes Tapes Tapes Tapes ...
Page 24: ...2H9 1 2 6 This page is intentionally left blank ...
Page 138: ...2H9 1 5 48 This page is intentionally left blank ...
Page 162: ...2H9 2 2 4 This page is intentionally left blank ...
Page 174: ...2H9 2 3 12 This page is intentionally left blank ...
Page 178: ...2H9 2 4 4 This page is intentionally left blank ...
Page 179: ......
Page 180: ......