2HJ/2HK
1-5-14
5. While releasing two release levers and then
remove the drum unit. (also 4 colors with the
same procedure, there is no order.)
6. Check or replace the drum unit and then
refit all the removed parts.
NOTE: When refitting the drum unit, insert
the FFC straightly to the FFC connector
when connecting the FFC.
Figure 1-5-16
Drum unit
(Yellow)
Release lever
Release lever
FFC
FFC connector
Contact
Drum unit
Drum unit
(Cyan)
Drum unit
(Black)
Drum unit
(Magenta)
Downloaded from
www.Manualslib.com