(4) Detaching and refitting the primary transfer cleaning unit
Procedure
1. Remove the primary transfer unit (See
page1-5-6).
2. Pull out the primary transfer cleaning unit
from the main unit frame a little with under-
neath the right (1).
3. Pull out the waste toner outlet (2) which is
on the left side of the primary transfer clean-
ing unit from the main unit frame.
4. Remove the primary transfer cleaning unit.
5. Check or replace the primary transfer clean-
ing unit and then refit all the removed parts.
Figure 1-5-37