2HJ/2HK
1-4-22
D020
Engine firmware error
Serious status inconsistency that is fatal
to keep controlling in the engine firm-
ware is detected.
Malfunction of the
engine firmware or
defective engine
firmware.
Turn the power off/on to restart the printer. If
the error is not resolved, check the update
information on the engine firmware. Update
the engine firmware as needed.
F000
Operation panel PWB communica-
tion error
The operation panel PWB (A0007) does
not communicate to the main controller
PWB (A0171) normally 30 seconds.
Defective main con-
troller PWB
(A0171).
Turn the power off/on to restart the printer. If
the error is not resolved, replace the main
controller PWB (A0171). See page 1-5-40.
Defective operation
panel PWB
(A0007).
Replace the operation panel PWB (A0007).
F020
Main controller PWB memory check
error
It could not access to the standard
memory or the optional expanding
memory which are mounted on the main
PWB (A0171) normally.
Defective main con-
troller PWB
(A0171).
Turn the power off/on to restart the printer. If
the error is not resolved, replace the main
controller PWB (A0171). See page 1-5-40.
Defective expand-
ing memory.
If the expanding memory is installed, after
removing or replacing the expanding mem-
ory, do the operation check. If operation is
normal, replace the expanding memory. See
page 1-3-8.
F030
Main controller PWB system error
The error which is related to the system
other than the error code F000, F010
and F020 occurred.
Defective main con-
troller PWB
(A0171).
Turn the power off/on to restart the printer. If
the error is not resolved, replace the main
controller PWB (A0171). See page 1-5-40.
F040
Engine controller PWB communica-
tion error
The main controller PWB (A0171) does
not communicate to the engine control-
ler PWB (A0004) normally.
Defective main con-
troller PWB
(A0171).
Turn the power off/on to restart the printer. If
the error is not resolved, replace the main
controller PWB (A0171). See page 1-5-40.
Defective engine
controller PWB
(A0004).
Replace the engine controller PWB (A0004).
See page 1-5-41.
F226
Main PWB video data control error
Defective main-
PWB.
Turn the power off/on to restart the printer. If
the error is not resolved, replace the main
controller PWB (A0171). See page 1-5-40.
Code
Contents
Remarks
Causes
Check procedures/corrective measures
Downloaded from
www.Manualslib.com
manuals search engine