2PX/2PY
2-4-12
Adjusting the scanner center line (alternative command for the maintenance mode U067)
Description
Adjusts the scanner center line of the original scanning.
Purpose
Make the adjustment if there is a regular error between the center lines of the copy image and original.
Example: Scanner leading edge registration set to 20 to increase 1.72mm
!R! KCFG “SCAN”,6,1,20;EXIT;
Format
!R! KCFG “SCAN”,6, #1;#2;EXIT;
Parameter
#1
1: Scanner center line
2: Scanner center line of rotated scan
#2
#1=1: Adjustable range: -70 to 70 (in 0.086mm increment) (0: default)
#1=2: Adjustable range: -40 to 40 (in 0.086mm increment) (0: default)
Original
Copy
example 1
Copy
example 2
Scanner center line (within ± 2.0 mm)