2PX/2PY
1-5-26
1-5-7 Fuser section
(1) Detaching and refitting the fuser unit
Procedure
1. Open the paper conveying unit.
2. Remove the IF cover (see page 1-5-3).
3. Remove the screw and then fuser wire
cover.
Figure 1-5-37
4. Remove three connectors.
5. Remove two screws and then remove
the fuser unit.
6. Check or replace the fuser unit and refit
all the removed parts.
*: Take care not to get the cables caught.
Figure 1-5-38
Screw
Fuser wire cover
Screw
Connectors
Connector
Screw
Fuser unit
Summary of Contents for 6026