2PX/2PY
2-3-2
Connector
Pin
Signal
I/O
Voltage
Description
YC101
1
LIVE
I
120 V AC
220-240 V AC
AC power input
Connected to
AC inlet and
main power
switch
2
NEUTRAL
I
120 V AC
220-240 V AC
AC power input
YC102
1
NEUTRAL
O
120 V AC/0 V
220-240 V AC/0 V
FH: On/Off
Connected to
fuser heater
2
LIVE
O
120 V AC
220-240 V AC
AC power to FH
YC103
1
+24V1
O
24 V DC
24 V DC power to RYPWB
Connected to
relay PWB
2
GND
-
-
Ground
3
GND
-
-
Ground
4
GND
-
-
Ground
5
GND
-
-
Ground
6
+24V2
O
24 V DC
24 V DC power to RYPWB (via ILSW)
7
+24V2
O
24 V DC
24 V DC power to RYPWB (via ILSW)
8
+24V2
O
24 V DC
24 V DC power to RYPWB (via ILSW)
9
+24V2
O
24 V DC
24 V DC power to RYPWB (via ILSW)
10
PSSLEEPN
I
0/3.3 V DC
Sleep mode signal: On/Off
11
ZCROSS
O
0/3.3 V DC (pulse) Zero-cross signal
12
RELAY
I
0/3.3 V DC
Power relay signal: On/Off
13
HEATRE1
I
0/3.3 V DC
FH: On/Off
YC104
1
+24V1
O
24 V DC
24 V DC power to ILSW
Connected to
interlock
switch
2
N.C
-
-
Not used
3
+24V2
I
24 V DC
24 V DC power from ILSW
YC105
1
+24V1
O
24 V DC
24 V DC power to MPWB
Connected to
main PWB
2
GND
-
-
Ground
3
GND
-
-
Ground
4
+5V1
O
5 V DC
5 V DC power to MPWB
Summary of Contents for 6026
Page 4: ...This page is intentionally left blank ...
Page 10: ...This page is intentionally left blank ...
Page 134: ...2PX 2PY 1 3 96 This page is intentionally left blank ...
Page 237: ...2PX 2PY 1 5 51 9 Remove the scanner unit Figure 1 5 78 Scanner unit ...
Page 275: ...2PX 2PY 1 5 89 4 Remove the paper conveying unit Figure 1 5 145 Paper conveying unit 1 2 2 ...
Page 280: ...2PX 2PY 1 5 94 This page is intentionally left blank ...
Page 323: ...2PX 2PY 2 2 10 This page is intentionally left blank ...
Page 371: ...1 1 INSTALLATION GUIDE INSTALLATION GUIDE FOR Card Authentication Kit D ...
Page 372: ...1 2 3 4 5 a a c CARD READER CARD READER HOLDER D b ...
Page 373: ...10 b c 6 8 9 7 ...
Page 375: ......