![Kyocera Mita KM-1500 Service Manual Download Page 35](http://html1.mh-extra.com/html/kyocera-mita/km-1500/km-1500_service-manual_2016984035.webp)
2DC
1-4-3
Section
Item
Maintenance item contents
Initial
No.
setting*
Fixing and
cleaning
Operation
panel and
support
equipment
Mode setting
Image
processing
Others
U161 Setting the fixing control temperature
• Primary stabilization fixing temperature
125
• Secondary stabilization fixing temperature
135
• Copying operation temperature 1
180
• Copying operation temperature 2
195
• Number of sheets for fixing control
5
U162 Stabilizing fixing forcibly
—
U163 Resetting the fixing problem data
—
U199 Checking the fixing temperature
—
U200 Turning all LEDs on
—
U203 Operating DP separately
—
U207 Checking the operation panel keys
—
U243 Checking the operation of the DP motors
—
U244 Checking the DP switches
—
U252 Setting the destination
Europe
U254 Turning auto start function on/off
On
U255 Setting auto clear time
90
U258 Switching copy operation at toner empty detection
Single mode
U260 Changing the copy count timing
After ejection
U265 Setting the destination specifications
0
U332 Setting the size conversion factor
1.0
U342 Setting the ejection restriction
On
U402 Adjusting margins for printing
—
U403 Adjusting margins for scanning an original on the contact glass
—
U404 Adjusting margins for scanning an original from the DP
—
U901 Checking/clearing copy counts by paper feed locations
—
U903 Checking/clearing the paper jam counts
—
U904 Checking/clearing the service call counts
—
U905 Checking/clearing counts by the DP
—
U908 Checking the total count
—
U910 Clearing the black ratio data
—
U911 Checking/clearing copy counts by paper size
—
U927 Clearing accounting counter
—
U990 Checking/clearing the time for the exposure lamp to light
—
U991 Checking the scanner count
—
U993 Outputting a VTC-PG pattern
—
* Initial setting for executing maintenance item U020