![Kyocera Mita KM-1500 Service Manual Download Page 135](http://html1.mh-extra.com/html/kyocera-mita/km-1500/km-1500_service-manual_2016984135.webp)
2DC
1-6-50
(10) Adjusting the DP magnification
Adjust magnification in the auxiliary scanning direction if magnification is incorrect when the DP is used.
U070
U065
(P. 1-6-46)
Caution:
Before making the following adjustment, ensure that the above adjustments have been made in maintenance mode.
Procedure
Auxiliary
scanning
direction
Original
Main scanning
direction
Copy
example 1
Copy
example 2
Enter maintenance mode.
Place an original on the DP
and make a test copy.
Yes
No
Start
End
Press the stop/clear key
to exit maintenance mode.
Is the image correct?
Enter “070” using the copy exposure
adjustment keys or zoom +/- keys.
Press the program key and the
machine enters the test copy mode.
Setting range: –25 – +25
Initial setting: 0
Changing the value by 1 changes
the magnification by 0.1%.
Increase the value makes
the image longer, and decreasing it
make the image shorter.
Change the setting.
• For copy example 1, increase
the value using the zoom (+)
key to make the copy image
longer.
• For copy example 2, decrease
the value using the zoom (-)
keys to make the copy image
shorter.
Press the start key.
Press the start key.
The new setting is stored.
Figure 1-6-60