background image

21

 

 

How to Change the filter

 

Gently push the filter into 
position (vertically inside the 
unit)

 

Close the filter cover. Plug the 
power in and open the valve 
to flush water for 3

-

5 minutes. 

This is to remove any loose 
particles from the filter. 

 

Run water until it clears 
before drinking.

 

8

 

Reconnect the electric 
connector to the filter 
monitoring sensor (PCB). Please 
refer to the above image, be 
careful with the electrical wire 
when you push the filter back 
into position.

 

9

 

Summary of Contents for Higen1+ Premium

Page 1: ...1 KYK Hydrogen Water Generator USER MANUAL Premium Higen1...

Page 2: ...Higen1 performance and extend the life span of the product All of our KYK executives and staff members are dedicated to achieving the best for our customers Our focus is on our customer benefits heal...

Page 3: ...lation checklist 15 8 How to use the Higen 1 16 9 When to change the filter 18 10 How to change the filter 19 11 Summary of Operation Notices 22 12 Notices for Safety 23 13 Product Specifications 24 T...

Page 4: ...ntrol Panel 6 buttons Speaker Filter Cover Bottom Tap Water IN Water OUT Overflow Leave open Power Cable ON OFF Valve Water OUT Overflow Drain Tap Water IN FlowDiverter Hose Tubing Accessories WaterPr...

Page 5: ...drogen Water Level 3 Hydrogen Water Cleaning Settings Purified Water Water ON OFF Valve Cleaning Setting Cleaning cycle starts automatically every 30 litres of continuous use to protect the electrolys...

Page 6: ...volume Press the Purified button for the low volume and the No 2 button for the higher volume The green LED indicator lights will light up as you switch between the two To apply the setting Press the...

Page 7: ...the purified button to move the green light to the left lower pH and the No 2 button to move the green light to the right higher pH To apply the setting Press the Clean Set button until the unit beeps...

Page 8: ...roduct at least 100mm away from any walls Damage can result from running hot water through the unit and will void any warranty Keep the product dry and avoid high moisture areas or direct sunlight Wat...

Page 9: ...tap if required Screw the Flow Diverter to the tap adaptor Slide the Water Softener on to the tube Attach the tube to the Pressure Reducing Valve PRV Use tubing to connect to the outlet of the PRV to...

Page 10: ...or break If connections are overtightened then leaks are possible And if connections are too loose then leaks are also possible For best result ensure connections are tight enough to not produce any...

Page 11: ...pply tubing to the elbow connector Caution Inlet and outlet check Ensure the water inlet and outlet are connected correctly Refer to Page 9 Unit Back diagram If the unit is used with the inlet IN and...

Page 12: ...RV between the tap flow diverter valve and the unit Standard tap adaptor rings are supplied with the Higen 1 These adaptors meet the Australian tap thread sizes standard and will fit most taps in Aust...

Page 13: ...r hand tight Then screw the adaptor ring diverter assembly to the tap use a little Teflon plumbers tape if needed taking care not to twist the hose Shortening hose from the flow diverter If you need t...

Page 14: ...lbow connector Read Caution below Plug in the power You will hear a start up sound and all lights will turn on for 3 seconds The hydrogen water level is automatically set to level 2 Push bar across on...

Page 15: ...urce water Ground bore rain or town water The Higen 1 is only suitable for town water supplies Contact us for more details on 1800 268 469 For areas with high limestone calcium in the water we supply...

Page 16: ...Hydrogen Water Cleaning Settings Purified Water Ozone Water Not for drinking Pull forward the faucet spout towards the front of the unit Press button for desired level or type of water An LED light wi...

Page 17: ...lifespan indicator lights will light up The lights indicate how much filter life is left for 3 seconds Then the lights will cycle on from left to right as the units is dispensing water Default settin...

Page 18: ...ty and service life of filter Filter life time will be effected by the quality of the source water Filter replacement time Filter life is 3000 litres or 12 months So replace the filter at 3000L or 12...

Page 19: ...ge the Filter Turn off the water How to change the filter Turn off the power to the unit and unplug it 4 3 2 Remove the filter cover by gently pushing down on the on the locking hock Gently tilt the f...

Page 20: ...lter 90 turn clock wise to lock it into position Make sure that the rubber ring in the connection between the filter and the main body is not detached or jammed Failure to do so may cause a water leak...

Page 21: ...and open the valve to flush water for 3 5 minutes This is to remove any loose particles from the filter Run water until it clears before drinking 8 Reconnect the electric connector to the filter moni...

Page 22: ...ct Do not lift this product body holding the faucet spout as it will break Do not drop shock or shake the unit It will cause internal damage Town tap water is best Do not use overly contaminated water...

Page 23: ...s such as rain your bathroom or your shower Do not place heavy objects on the Higen 1 unit Install the Higen 1 unit on a solid and horizontal countertop or shelf Only use cold water with the Higen 1 u...

Page 24: ...cation filter life Electrolysis Performance Output Hydrogen Rich Water 0 7 0 8 L min 10 Water Type 3 levels of hydrogen water 1 purified and 1 ozone water Electrolysis Cell PEM Electrode Cleaning PEM...

Page 25: ...ir the unit themselves or the unit is repaired by an unauthorized service center d Damage is caused by using the incorrect electrical voltage e Damage is caused by using an imitation filter f Damage i...

Page 26: ..._______________________________________ ________________________________________________________________ ________________________________________________________________ ______________________________...

Page 27: ..._______________________________________ ________________________________________________________________ ________________________________________________________________ ______________________________...

Page 28: ...and respectfully with their health and happiness our number one priority The head office address Manufacturing Company 407 410 Sun il technopia 555 Dunchon road Joongwon Gu Sungnam City Kyunggi Do KOR...

Reviews: