MANUAL
EFU10000
4.0kVA INVERTER UNIT
Pag. 20
/ 34
7.4 M
OUNTING AND CONNECTING THE INVERTER
NOTE
WARNING
Use correct silent blocks to avoid direct transmission of any vibrations to
the inverter (see paragraph 11.12.3 for the limits).
Before to start the engine it is preferable that all the appliances stay
switched off.
Start the engine and make sure the AC output indicator comes on.
When an extension cable is required, be sure to use a tough rubber sheathed
flexible and fireproof cable. Limit length of extension cables depends on the
voltage drop along the cable. This drop must be lower than 2.5% value of
the nominal output voltage.
Keep the generator away from other electrical cables or wires such as
commercial power supply lines.
Most appliance motors require more than their rated wattage for start-up.
Use a threaded hole of the heat sink for connecting the external ground
source to the inverter.
KEEP OUT OF REACH OF CHILDREN.
7.5 S
WITCHING OFF THE INVERTER
In order to provide sufficient time to the inverter for the saving of the internal parameter and
diagnostic codes, it is important to previosly detach all the loads before switching off the inverter
power supply.