MANUAL
EFU10000
4.0kVA INVERTER UNIT
Pag. 32
/ 34
11.12. A
PPLICABLE
S
TANDARDS
7
11.12.1. M
ARKING
A
CCORDING TO
11.12.1.1
Safety
EN 60950 - Protection Class I
11.12.1.2
Emission for Residential,
Commercial
and
Light-
Industrial Enviroments
EN 61000-6-3
11.12.1.3
Conducted Emission for
Industrial Enviroments
EN 61000-6-4
11.12.1.4
Immunity for Industrial
Enviroments
EN 61000-6-2
11.12.1.5
Construction Machinery -
Electromagnetic
Compatibility of Machines
with Internal Power Supply
EN 13309
11.12.2. S
EALING
P
ROTECTION
L
EVEL
8
11.12.2.1 Sealing protection
level IP
IP 00
11.12.3. V
IBRATIONS
9
11.12.3.1.
Along X and Y axis
3.5g - Sinus between 10÷80Hz
11.12.3.2.
Along Z axis (vertical)
4g – Sinus between 10÷80Hz
11.12.3.3.
Shock along X axis front direction
5 g
11.12.3.4.
Shock along X axis back direction
5 g
11.12.3.5.
Shock along Y axis
5 g
11.12.3.6.
Shock along Z axis top direction
5 g
11.12.3.7.
Shock along Z axis bottom direction
5 g
7
The applicable standards compliance is out of the offer for the first prototypes. This compliance will be quoted
separately after validation of the first prototypes when power supplied by customer’s motor and concerning the main
electrical characteristics detailed in paragraph 11.
8
The reaching of a sealing protection level IP 67 depends completely on the enclosure made by the customer.
9
Vibrations test to be performed and fixed by customer or quoted separately by
KWG.