Connecting the Terminal Strip Connectors to the ADCU
Now that you have connected all wires to the terminal strip
connectors, insert the connectors into the ADCU’s rear panel as
shown in Figure 2-29.
Be sure to attach the terminal strip connectors in their correct
positions, as shown in Figure 2-30.
54-0147
38
TracVision G4 Technical Manual
#
!!
!
!
!
'
&
%
$
!$
!#
!"
!
'
&
%
$
#
"
"
!
'
&
%
$
#
"
!
Figure 2-29
Attaching the Terminal Strips
to the ADCU
1
2
11
10
9
8
7
6
12
5
4
3
13 14
23
22
21
20
19
18
24
17
16
15
25 26
35
34
33
32
31
30
36
29
28
27
48 47
38
39
40
41
42
43
37
44
45
46
60 59
50
51
52
53
54
55
49
56
57
58
Maintenance Port
Connectors 1 - 36
Connectors 60 - 37
Yellow Label
Red Label
Green Label
Blue Label
White Label
Figure 2-30
Proper Terminal Strip Order
Double-check all wiring. Be certain
to plug terminal strips into the
correct positions. If wiring is
incomplete or incorrect or the
terminal strips exchange positions,
serious electrical damage can
occur to the TracVision antenna
unit, the GyroTrac, and interfacing
electronics.
Summary of Contents for TracVision G4
Page 127: ......