Chapter 5: Troubleshooting
216
Status signalling
01110 to
01119
Temperature too
high (critical)
Terminal:
Critically
high temperature is
causing the terminal
to shut down.
Antenna:
Critically
high temperature is
causing the antenna
to stop transmission.
If possible, move the
failing unit to a
cooler location.
For information on
ambient temperature
limits, see the
installation manual.
Contact your
distributor if the
problem persists.
01120 to
01129
Too high
temperature
warning
High ambient
temperature is
causing the
performance of the
system to be
degraded or halted.
If the problem is in
the terminal: All PoE
ports are shut down,
except port 1 and the
bit rate for Standard
data is reduced.
If the problem is in
the antenna: The bit
rate is reduced.
Move the terminal to
a cooler location.
For information on
ambient temperature
limits, see the
installation manual.
01300 to
01309
No GPS fix
The GPS receiver has
not yet achieved
position fix.
Make sure the view
to the GPS satellites
is not blocked.
Note that in some
cases it may take up
to 10 minutes to
obtain GPS fix.
ID
Event Text
Explanation
Remedy