SECTION 6 - TESTING PROCEDURES
6.2
6.3 MANUAL TEST
The operator can manually perform the indicator and
internal tests at any time during normal radar operation—
just press and release the Test switch. The indicator test
will be performed followed by the display of “PAS” in the
TARGET window in Stationary Mode and in both Target
and PATROL windows in Moving Mode.
NOTE:
The unit will remain in the TEST state for 30 seconds
after releasing the TEST switch, indicated by the
flashing TEST indicator.
6.4 SPEEDOMETER VERIFICATION
Before the Falcon HR can be used with the speedometer
pulse input, the radar unit must be synchronized with the
speedometer.
1. After installation, the Falcon HR should be driven at a
constant speed, between 48 and 112 km/h. Press the
PAT SEL switch on the remote control twice. “Snc”
will appear in the TARGET window and patrol speed
will appear in the PATROL window.
2. Verify the patrol speed displayed matches the
speedometer reading, and press the LOCK/REL switch.
This tells the DSP processor that the current
speedometer reading and the Doppler patrol reading
agree, within speedometer tolerance limits.
3. Within two (2) seconds, a synchronization number will
appear in the LOCK window. Typically this number
will be around 50 for Ford products. This indicates the
Falcon HR is reading and comparing the speedometer
speed input and the true Doppler patrol speed.