SECTION 6 - TESTING PROCEDURES
6.1
6. TESTING PROCEDURES
6.0 GENERAL
The internal circuit and antenna tests are periodically
performed automatically while the unit is in use.
6.1 POWER ON
Press and release the PWR switch. The unit will turn on
all the LCD segments for a display test and perform a
crystal cross check to verify the accuracy of the speed
processing circuitry.
If these tests pass, the unit will display “PAS” in the
TARGET display window, stationary mode, or in both
TARGET and PATROL display windows in the moving
mode. This will remain for approximately one (1) second.
The displays will clear and the unit will be operational.
6.2 AUTOMATIC SELF-TEST
As long as the unit is turned on, the Falcon HR performs an
internal accuracy test every 5 minutes or whenever the
unit’s mode of operation is changed, such as moving to
stationary, and each time the target speed is locked.
This test is automatic and will not interfere with any radar
speed readings being taken. The test passing does not
appear in the displays, but if an error is detected during this
test, the TARGET window will indicate “Err” and further
speed-readings are prohibited.