I. SAFETY :

This  manual  contains  information  and  warnings  that  must  be 
followed  for  operating  the  instrument  safely  and  maintaining  the 
instrument in a safe operating condition. If the instrument is used in
manner not specified by the manufacturer, the protection provided
by the instrument may be impaired.

Terms in this manual :

WARNING

Identifies  conditions  and  actions  that  could result in 
serious injury or even death to the user.

CAUTION

Identifies   conditions  and  actions   that  could  cause
damage or malfunction in the instrument.

01

22

MUMBAI

TEST CERTIFICATE

AC TRMS DIGITAL CLAMPMETER

This Test Certificate warrantees that the product has been 

inspected  and  tested  in  accordance  with  the  published 

specifications.

The  instrument  has  been  calibrated  by  using  equipment 

which has already been calibrated to standards traceable 

to national standards.

MODEL NO. ________________

KM 175D

SERIAL NO. ___________

DATE: ___________

ISO 9001

REGISTERED

QC

PASS

KUSAM-MECO

WARNING :

To reduce the risk of fire or electric shock, do not expose this product
to rain or moisture. The meter is intended only for indoor use.

Keep your hands/fingers behind the hand/finger barriers (of the meter
and the test leads) that indicate the limits of safe access of the hand-
held  part  during  measurement.  Inspect  test  leads,  connectors  and 
probes  for  damaged  insulation  or  exposed  metal  before  using  the 
instrument. If any defects are found, replace them immediately. Only
use  the  test  lead  provided  with  the  meter  or  UL  Listed  Probe 
Assembly to the same meter ratings or better.

IEC  61010-031  requires  exposed  conductive  test  probe  tips  to  be 
< 4mm for CAT III & CAT IV ratings. Refer to the category markings 
on  your  probe  assemblies  as  well  as  on  the  add-on  accessories 
(like  detachable  Caps  or  Alligator  Clips),  if  any,  for  applicable
rating changes.

Observe  proper  safety  precautions  when  working  with  voltages 
above 33 Vrms, 46.7Vpeak or 70 VDC. These voltage levels pose 
a potential shock hazard to the user. Before and after hazardous 
voltage  measurements,  check  the  voltage  function  on  a  known 
source such as line voltage to determine proper meter functioning.

Summary of Contents for KM 175D

Page 1: ...rature 20 C 60 C 80 R H with battery removed o o o o o Temperature Coefficient Nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Battery x...

Page 2: ...52 F 1 0 0 8 C Accuracy1 2 1 0 1 C 1 0 1 5 F 1 0 2 F 1 2 K type thermocouple range accuracy not included Accuracies assume meter interior has the same temperature of the ambient isothermal stage for a...

Page 3: ...ometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequ...

Page 4: ...dent or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a gre...

Page 5: ...WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture The meter is intended only for indoor use Keep your hands fingers behind the hand finger barriers o...

Page 6: ...ve conductors But still individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible CAUTION Disconnect the test...

Page 7: ...range Backlighted LCD display Duo Core to simultaneously measure clamp on Amps A DMM functions VFD V Hz for fundamental V Hz of most Variable Frequency Drives Display Hold Non Contact EF Detection NC...

Page 8: ...abled automatically in this mode Hold feature freezes the display for later view LCD turns on Press the HOLD button momentarily to toggle the hold feature The Complementary Beeper feature can be selec...

Page 9: ...lead terminals COM Application Notes on Flame Sensors The DCmA function is designed especially for HVAC R flame sensor applications The 0 1 mA resolution is useful for identifying the minute current...

Page 10: ...nt 0 60A kV 50 60Hz 3 Specified accuracy is for measurements made at the jaw center When the conductor is not positioned at the jaw center add 2 to specified accuracy for position errors 4 Induced non...

Page 11: ...must be disconnected from the circuit to obtain an accurate measurement reading Capacitance Diode functions Inputs are made through the test lead terminals COM Defaults at Capacitance Press SELECT bu...

Page 12: ...from 2 of range CAUTION Using Resistance Continuity function in a live circuit will produce false results and may damage the meter In many cases the suspected component s must be disconnected from the...

Page 13: ...0 W W Response Time 32ms approx 3 000 V 1 5 rdg 5dgts DIODE TESTER Accuracy Resolution Range 1 mV Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typical Non Contact EF Detection NCV An anten...

Page 14: ...00V CAT III 300V CAT IV V W Hz EF V OFF AUTO H P RMS 8 8 8 8 mFA V VFD P RMS SELECT HOLD COM CAT III 600V CAT IV 300V 2 3 1 4 6 10 mA A AUTO kW Hz 6 1 7 5 Duo The detected Electric Field strength is i...

Page 15: ...much as possible to get the best measuring accuracy For removal press the jaw trigger and remove the jaws from the conductor s CAUTION Adjacent current carrying devices such as transformers motors an...

Reviews: