Kusam-meco KM 175D Operation Manual Download Page 14

®

®

10

VI. PRODUCT DESCRIPTION :

This  manual  uses  only  representative  model(s)  for  illustrations. 
Please refer specification details for function availability to this model.

1. Antenna  area  for  Non-Contact  EF-

Detection

3. Rotary  Selector  to  turn   the  power 

ON/OFF and Select a function.

4. 3-5/6 digits 6000 counts Dual numeric

LCD display.

6. Input Jack for all functions EXCEPT

non-invasive  ACA current function.

7. Common (Ground reference) Input

Jack  for  all  functions EXCEPT non-
invasive ACA current functions.

8. Push-buttons  for  special  functions  &

features.

9. Jaw trigger for opening the clamp jaw.

10. Hand/Finger  Barrier  to  indicate  the

limits of safe access of the meter.

11. Clamp  Jaw  for   AC   current

magnetic field pick up.

12. Additional  center  indicator  for 

TM

AmpTip   Low-current  function,  at

TM

where best AmpTip  current accuracy
is specified.

2. Jaw  center  indicator at where best 
    current accuracy is specified.

7

8

9

11

12

 

MAX 600A

600V CAT III
300V CAT IV

V

W

Hz
EF

V

OFF

AUTO

H

P-RMS

8.8.8.8

m

F

A

V

VFD

+ –

P-RMS

SELECT

HOLD

COM

+

CAT III

600V

CAT IV

300V

2

3

1

4

6

10

m

A

A

AUTO

k

W

Hz

6. 1.7.5

/

Duo

The  detected  Electric  Field  strength  is  indicated  as  a  series  of 

bar-graph  segments  on  the  display  together  with  variable  beep 

tones.  Two  user  selectable  sensitivities  are  available.  In  High 

Sensitivity range, the meter displays 

"EF-H" 

when it is ready. It is

set to better detect lower voltage signals. If it is too sensitive for 

your applications, press 

SELECT 

button momentarily to use the 

Lower Sensitivity 

“EF-L" 

range

EF-Detection function with EF-H & EF-L Sensitivities

 

MAX 600A

600V CAT III
300V CAT IV

V

W

Hz
EF

V

OFF

00.00

P-RMS

SELECT

HOLD

COM

+

CAT III

600V

CAT IV

300V

m

A

A

EF-H

/

1

SELECT

Duo

 

MAX 600A

600V CAT III
300V CAT IV

V

W

Hz
EF

V

OFF

00.00

P-RMS

SELECT

HOLD

COM

+

CAT III

600V

CAT IV

300V

m

A

A

/

1

SELECT

Duo

 

MAX 600A

600V CAT III
300V CAT IV

V

W

Hz
EF

V

OFF

00.00

P-RMS

SELECT

HOLD

COM

+

CAT III

600V

CAT IV

300V

m

A

A

/

Duo

EF-H

 

MAX 600A

600V CAT III
300V CAT IV

V

W

Hz
EF

V

OFF

00.00

P-RMS

SELECT

HOLD

COM

+

CAT III

600V

CAT IV

300V

m

A

A

/

Duo

Live

Ground

13

Summary of Contents for KM 175D

Page 1: ...rature 20 C 60 C 80 R H with battery removed o o o o o Temperature Coefficient Nominal 0 15 x specified accuracy C 0 C 18 C or 28 C 40 C or otherwise specified Power Supply Standard 1 5V AAA Battery x...

Page 2: ...52 F 1 0 0 8 C Accuracy1 2 1 0 1 C 1 0 1 5 F 1 0 2 F 1 2 K type thermocouple range accuracy not included Accuracies assume meter interior has the same temperature of the ambient isothermal stage for a...

Page 3: ...ometer Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequ...

Page 4: ...dent or abnormal conditions of operation or handling KUSAM MECO authorized dealer shall extend this warranty on new and unused products to end user customers only but have no authority to extend a gre...

Page 5: ...WARNING To reduce the risk of fire or electric shock do not expose this product to rain or moisture The meter is intended only for indoor use Keep your hands fingers behind the hand finger barriers o...

Page 6: ...ve conductors But still individual protective equipment must be used if hazardous live parts in the installation where measurement is to be carried out could be accessible CAUTION Disconnect the test...

Page 7: ...range Backlighted LCD display Duo Core to simultaneously measure clamp on Amps A DMM functions VFD V Hz for fundamental V Hz of most Variable Frequency Drives Display Hold Non Contact EF Detection NC...

Page 8: ...abled automatically in this mode Hold feature freezes the display for later view LCD turns on Press the HOLD button momentarily to toggle the hold feature The Complementary Beeper feature can be selec...

Page 9: ...lead terminals COM Application Notes on Flame Sensors The DCmA function is designed especially for HVAC R flame sensor applications The 0 1 mA resolution is useful for identifying the minute current...

Page 10: ...nt 0 60A kV 50 60Hz 3 Specified accuracy is for measurements made at the jaw center When the conductor is not positioned at the jaw center add 2 to specified accuracy for position errors 4 Induced non...

Page 11: ...must be disconnected from the circuit to obtain an accurate measurement reading Capacitance Diode functions Inputs are made through the test lead terminals COM Defaults at Capacitance Press SELECT bu...

Page 12: ...from 2 of range CAUTION Using Resistance Continuity function in a live circuit will produce false results and may damage the meter In many cases the suspected component s must be disconnected from the...

Page 13: ...0 W W Response Time 32ms approx 3 000 V 1 5 rdg 5dgts DIODE TESTER Accuracy Resolution Range 1 mV Test Current 0 3mA typically Open Circuit Voltage 3 5VDC typical Non Contact EF Detection NCV An anten...

Page 14: ...00V CAT III 300V CAT IV V W Hz EF V OFF AUTO H P RMS 8 8 8 8 mFA V VFD P RMS SELECT HOLD COM CAT III 600V CAT IV 300V 2 3 1 4 6 10 mA A AUTO kW Hz 6 1 7 5 Duo The detected Electric Field strength is i...

Page 15: ...much as possible to get the best measuring accuracy For removal press the jaw trigger and remove the jaws from the conductor s CAUTION Adjacent current carrying devices such as transformers motors an...

Reviews: