Operating Manual

KE3500

xDSL M

ULTI

T

EST

Version 1.0 / 05/2014 - Copyright 2014  KURTH ELECTRONIC GmbH

All rights reserved, including translations.

All reprints and electronic copies, including excerpts, 
require prior written approval of Kurth Electronic GmbH.

All of the brand names and trademarks cited herein are the property of 
their registered owners.

®

Summary of Contents for 0.49810

Page 1: ...4 KURTH ELECTRONIC GmbH All rights reserved including translations All reprints and electronic copies including excerpts require prior written approval of Kurth Electronic GmbH All of the brand names...

Page 2: ...Power supply connection Ethernet 10 100 Management Ethernet 10 100 1000 Test Port and optional ISDN Interface Operating Manual KE3500 xDSL MULTITEST 2 KURTH ELECTRONIC Test Measurement www kurthelect...

Page 3: ...hrzeit Datum Uhrzeit Datum Showtime Showtime 4 Safety Instructions The KE3500 may only be operated with the accessories originally provided Using the device with accessories that are not original or f...

Page 4: ...16 KE Manager Software 19 Changing the LiPo Battery 20 ISDN and Analog Interface optional 21 ISDN Testing 21 BERT Testing 22 Analog Testing 23 Copper Testing with KECT3 optional 24 Operation 24 Conne...

Page 5: ...unctionality the user can scroll between the windows Without the loss of the current synchronization other parameters or tests can be added and thus enables fast easy and comprehensive diagnosis KE Ma...

Page 6: ...and LEFT RIGHT To move in graphical views around the vertical axis use Keypad Alphanumeric keypad with 1 0 A Z special characters Text input F1 abc 123 Switch between letters and numbers input Specia...

Page 7: ...cates that the power supply or charger is inserted and is supplying power The red LED signals that the battery is in charging mode This produces a green red or orange display during charging Once cont...

Page 8: ...three pin plugTF ISDN interface optional ISDN and analogue connections RJ11 and RJ45 LINE 1 LINE 2 A A B B GND GND GND GND TIP TIP RING RING USB 1 SD 100 Mb Management 1000 Mb xDSL Test Port POTS ISDN...

Page 9: ...n switch between parameters by pressing the buttons When the entry is without the arrows press SEL SELECT to move to a submenu where you can change settings Press ESC to exit and save the selection in...

Page 10: ...for Batt Chrg must light up green or green and red orange Power loss during update upgrade can have the consequence that the KE3500 stops working and needs to be returned to the manufacturer The poss...

Page 11: ...sert errors shown errors will n be set to zero Save measurement or directly n during the measurement by pressing the SEL key It opens up a Window where the file name can be entered as a name number Af...

Page 12: ...ible with the supplied KE Manager QR code generation When you press the 7 key a QR code is calculated from a portion of the displayed data This is then displayed on the screen and can be read with app...

Page 13: ...draw conclusion errors Save the measurement with SEL exit with ESC The Ethernet interface is transparently switched to have the modem functions Terminal Mode Ethernet Connection to the Ethernet inter...

Page 14: ...Operating Manual KE3500 xDSL MULTITEST 14 KURTH ELECTRONIC Test Measurement www kurthelectronic de info kurthelectronic de Data Test Description available soon...

Page 15: ...Operating Manual KE3500 xDSL MULTITEST 15 KURTH ELECTRONIC Test Measurement www kurthelectronic de info kurthelectronic de Data Test Description available soon...

Page 16: ...minal Main Menu Always On 3 minutes 60 minutes Always Off Always On 3 minutes German English Input Execution 1 Automatic Off 2 Backlight Brightness Dimmed 3 Language 4 Date Time 5 Software Updates 6 S...

Page 17: ...Re Sync 4 xDSL Mode 5 Seamless Rate Adaption 6 ATM Type 7 VPI 8 VCI 9 PTM Priority 0 VLAN Tagging Encapsulation Authentication Annex A M Annex B J Off On Off On AAL5 AALOPKT AALOCEIL 0 255 32 65 535...

Page 18: ...EIL PPPoA PPPoE IPoA IPoE 0 255 32 65 535 0 4 095 Off On 1 Auto Re Sync 3 Seamless Rate Adaption 4 ATM Type 5 Encapsulation 6 VPI 7 VCI 8 VLAN Tagging 9 Authentication 56 2 048 Bytes Off On On On Gene...

Page 19: ...remain in the network It will automatically determine an IP address UPnP address and the KE3500 appears with the IP address and serial number in the select list of the KE Manager Opening the KE Manag...

Page 20: ...ay goes below 50 you need to change the battery You can either send in the device and the battery will be changed for a fee or you can order a replacement battery Changing the battery First remove the...

Page 21: ...connection service and service feature tests Under Interface you can choose between the connection types of Analog ISDN S0TE ISDN S0 NTand ISDN Uk0 Telephone ISDN S0 TE Enter a telephone number in th...

Page 22: ...pattern Differences are counted as bit errors Services Service Request Under the Service Request menu item the important service features and whether they are supported by the dialed connection are c...

Page 23: ...either the DTMF or IWV dialing mode can be set Setup Telephony analog Under this menu item you will find the basic setups for the telephony test that are possible depending on the selected inter face...

Page 24: ...he subscriber line from ADSL to VDSL2 n Automatic test programs provide detailed measurement results n Parameter editor to change the system and cable parameters n PC interface for data transfer to a...

Page 25: ...meters by the input of only two values such as the cable diameter and the resistance per meter R the remaining copper cable parameters are calculated from KECT3 Only the cable manufacturer specified V...

Page 26: ...ound A GND B GND Insulation In this setting KECT3 measures the insulation resistance between the two wires running a pair of wires and the individual wires and ground Measurement method Connect the wi...

Page 27: ...ically thereafter Up in the display the specification of the used copper parameter is shown Capacitance is indicated and the cable length calculated from the capacitance is displayed in meters Under F...

Page 28: ...this page by pressing ESC which terminates the loop analysis Press F2 Load to load a previously saved configuration and press F3 Save to save the current configuration Press F4 Start to start the loop...

Page 29: ...f the screen and is the basis for the following measurements for line qualification No higher service setting frequency is required to per form the measurements Disturbances in the high frequency rang...

Page 30: ...nuation measurements Balance Longitudinal currents can cause noise on the line if the symmetry is imperfect The line balance is the ability of the line to suppress the effect of longitudinal currents...

Page 31: ...value and with Max the upper value of the graphic are pre defined Measurement results The measurement results are available both graphically and numerically and are displayed simultaneously Indicated...

Page 32: ...ity Contributors to noise include balance faults crosstalk and poor connections to the switched telephone lines The noise level is shown as single value in dBm Measurement method Select the mode Wideb...

Page 33: ...The noise pulse is a voltage whose value is at least 12 dB higher than the power level of the background noise The KECT3 works as noise pulse counter A pulse is counted when the voltage of the receive...

Page 34: ...e CO side Connect Port 1 2 Port 1 connected to Port 2 Used to restore the subscriber s line before and after testing Connect Port 1 3 Port 1 connected to Port 3 Atest set on Port 3 can then be used fo...

Page 35: ...of the impedance change Finds cable faults such as short circuit opens bridge taps bad splices water penetration and other damage such as lightning strikes crushed cable etc which changes the impedanc...

Page 36: ...de 5 060 UDP RTP Port 6 p q xxxxxxxxx Stun Server 7 8 Off 0 1 65 353 Off On UDP RTP Port Range Registrar 8 Off Off On Proxy 8 Off Off On Input Input Input Input 1 65 353 Data VoIP IPTV Line Date Time...

Page 37: ...xJ EU 60 Infineon ATU R Annex B J Showtime a b 0 0 V 1 2 3 4 0 32 22 p q VoIP Log Tests More Views Description Waiting for Network Interface Connecting to SIP server Connected to SIP server Call sip X...

Page 38: ...HD BR Sd HD NDR HD SWR BW HD SWR RP HD WDR HD 3sat HD ARTE HD KIKA HD 8 Data VoIP IPTV Line Date Time G992 5 ADSL2 AnnexJ EU 60 Infineon ATU R Annex B J Showtime a b 0 0 V 1 2 3 4 0 32 22 p q IPTV Log...

Page 39: ...Operating Manual KE3500 xDSL MULTITEST 39 KURTH ELECTRONIC Test Measurement www kurthelectronic de info kurthelectronic de IPTV optional...

Page 40: ...is formally specified in RFC 1994 In contrast to PAP more value is placed on security when transmitting the passwords DTMF The multiple frequency method is the conventional dialing technique used in...

Page 41: ...eb WWW into a web browser HTTP is one of the application layer established network models The application layer is addressed by the application programs and in the case of HTTP this is usually a web b...

Page 42: ...technical terminology as an NTBBA Network Termination Broad BandAccess is a device for transmitting data by way of a subscriber line using DSL technology It forms the network termination for the DSL...

Page 43: ...connection to the Internet for the secure connection of several locations Virtual Private Network or for the direct connection of several local network segments with adaptation to different network pr...

Page 44: ...y the selection of a different path in the case of a network overload and other factors URL AUniform Resource Locator URL identifies and localizes a resource such as a website by way of the access met...

Page 45: ...data flat rate is an advantage because this creates a large amount of data traffic VoIP IP Telephony short for Internet Protocol telephony also known as Internet Telephony or Voice over IP VoIP for sh...

Page 46: ...unter Power supply 100 230 V AC 50 60 Hz Delivery Standard Equipment AC power supply and charger test leads RJ11 RJ45 RJ11 banana plug with rubber insulated crocodile clips Ethernet cable rugged cordu...