23
For internal use only
10.3
AromaControl
The full element can only be replaced if the door is dismantled. However, the valve may also be replaced
without a casing. In this case the door will not need to be dismantled.
1.
Remove the cover with a small screw driver, making sure
that the casing is not scratched.
2.
Remove the knob (B).
3.
Remove the water channel (A).
4.
Then remove all five screws off the flange.
5.
Remove the brewing unit from the back.
10.4
Flap support
The bracket at the top will break (see arrow) if the screw driver is
incorrectly positioned. The snapper will be defect and will need to
be replaced. To do so you will have to remove the appliance, i.e.
pull it slightly out of the niche.
Old pegs must also be disposed of. The new peg has been
modified, which has greatly enhanced its closing force.
A
B