background image

22

For internal use only

2.

Loosen the screws and remove the metal plate inserted in
the door.

3.

Remove the brass bush with the lock washer and then the
hinge.

4.

Remove the other screws.

5.

Pull the coffee dispenser right out.

10.2

Door lock

1.

Loosen the screws.

2.

Pull the lock upwards.

Z

Attention!
Do not lose the spring!

Summary of Contents for cafe profi EKV 6600.0

Page 1: ...Built in fully automatic coffee machine EKV 6600 0...

Page 2: ...ice Manual H6 72 01 Responsible Mario K hne K PPERSBUSCH HAUSGER TE AG Email mario kuehne kueppersbusch de Tel 0209 401 756 Kundendienst Fax 0209 401 743 Postfach 100 132 Date 21 12 06 45801 Gelsenkir...

Page 3: ...13 6 2 Button assignment in the programming mode 13 7 User settings 14 8 Fittings 16 8 1 Aroma Control 16 8 2 Water tank 16 8 3 Grinder 17 8 4 Brewing unit 17 8 5 Two separate heating systems 17 8 6...

Page 4: ...box does not close 32 12 6 Coffee is not dispensed uniformly or is dispensed without flowing 32 12 7 Coffee tastes bitter 33 12 8 Coffee tastes bland 33 12 9 Coffee tastes rancid 33 12 10 The coffee...

Page 5: ...0701 the boiler must be tested for insulation faults by means of direct measurement or the differential current of the appliance must be measured Beware of the sharp edges of stainless steel units whe...

Page 6: ...e operation or incorrect handling liability cannot be assumed for any resulting damage Never operate a defect appliance or an appliance with faulty cables The manufacturer of the prod uct will assume...

Page 7: ...lance N Bar handle to open the panel O Clear text display P Control panel Q Rotating knobs for aroma control R Nozzle S Service flap T Coffee dispenser Drip tray U Box for coffee grounds V Drip tray M...

Page 8: ...The features LED lighting Central switch off device Adjustable coffee dispenser height Electronic push buttons Electronic clock with a minute minder Pre set time Standby mode Programming quantities f...

Page 9: ...age Overall dimensions Height 38 0cm Width 59 6cm Depth 32 6cm Weight 13kg Niche dimensions WxDxH 560 x 450 x 381mm Connected load in KW 1250W Voltage V 230V 50Hz Fuse 10A Connecting cable 1 20m Ready...

Page 10: ...d on installation The appliance may only be connected to a properly installed wall outlet The connection cable should only be replaced by an electrician in observance of the relevant regulations Safet...

Page 11: ...11 For internal use only 5 3 Installation in a top unit 5 4 Installation in a tall unit at least 570mm without a front door at least 550mm...

Page 12: ...12 For internal use only The height can possibly be regulated with the adjusting screw clearances flush mounting...

Page 13: ...ing standby user settings Dispensing 1 cup of coffee large Dispensing 1 cup of coffee Dispensing 1 cup of espresso Dispensing hot water Dispensing steam Red clear text display 6 2 Button assignment in...

Page 14: ...h and Dutch language German ENGLISH Contrast contrast The contrast setting for the clear text dis play can be made in 10 stages Lighting lighting Use ON or OFF to switch the lighting on or off Water h...

Page 15: ...etting is at long the coffee will be pre brewed for 4 seconds Total coffee total coffee The total number of coffee portions being dispensed is shown Timer Timer machine off after xx xx Choice of time...

Page 16: ...b in the middle Slow brewing process Optimal extraction of flavour Medium water pressure Little water Minimum setting for strong coffee ristretto type Turn the aroma knob clockwise until it stops Slow...

Page 17: ...rings out the full aroma and is the heart of all fully automatic coffee machines It is simple to remove and easy to clean 8 5 Two separate heating systems The new fully automatic built in coffee machi...

Page 18: ...g the water filter 9 1 Operating principle The AquaPrima water filter takes effect in a number of ways the charcoal activated carbon reduces the occurrence of substances that have a detrimental effect...

Page 19: ...talled it is the user settings that are decisive If the machine is operated without a filter it is essential that the water filter setting be set at OFF 9 2 Inserting the AquaPrima water filter 1 Swit...

Page 20: ...Pump Steam boiler Excess pressure Power module Micro fuses Coffee water Valve Safety fuse Excessive boiler safety fuse temperature valve Z The brewing unit must be set at zero before the brewing syst...

Page 21: ...e dispenser will need to be replaced if it no longer engages properly since this means that the catch is defect 1 Remove the entire flap Final switch brewing unit normal position Final switch service...

Page 22: ...he metal plate inserted in the door 3 Remove the brass bush with the lock washer and then the hinge 4 Remove the other screws 5 Pull the coffee dispenser right out 10 2 Door lock 1 Loosen the screws 2...

Page 23: ...ched 2 Remove the knob B 3 Remove the water channel A 4 Then remove all five screws off the flange 5 Remove the brewing unit from the back 10 4 Flap support The bracket at the top will break see arrow...

Page 24: ...Loosen the splint 2 Remove the screws 3 Swing the swivel nozzle out towards the front 4 Turn it by a turn and pull it out Assembly 5 First push the nozzle and then turn it by a turn until it engages 6...

Page 25: ...only 10 6 Brewing unit sieve Z Attention Carefully tighten the sieve with a spanner or by hand If the sieve is too tight the brass bush may loosen and come out of the shell This may cause the brewing...

Page 26: ...ent Never rinse parts of the machine in the dishwasher and never dry them in the oven or in the microwave Water tank coffee bean box 1 Switch off the appliance 2 Remove the tank box 3 Clean the tank a...

Page 27: ...nt 4 Slide the coffee dispenser onto the holder again until it engages Brewing unit 1 Slide the drip safeguard onto the AromaControl and remove the drip tray 2 Open the service flap The push button is...

Page 28: ...is being descaled the descaling process will be resumed when the machine is switched on again Descaling will take approx 30 minutes Water hardness Attention 1 2 litre water with an antiliming agent is...

Page 29: ...e appliance press the water button appears in the display Rinsing 1 Rinse the water tank thoroughly and fill it up with fresh water 2 Press button P in order to start the rinsing cycle Button can be u...

Page 30: ...the display does not show up the float solenoid valve will have become caught in the water tank as a result of limestone and will need to be cleaned 12 2 Ventilate permanently is shown Switch the app...

Page 31: ...ied and or that the O ring is not defect 2 To do so screw the O ring off 3 Remove the valve 4 Clean the parts and replace them if necessary 12 3 Water is not dispensed or is dispensed with insufficien...

Page 32: ...ill flow out normally when the aroma is regulated in the middle thus guaranteeing the best possible flow If the flow volume is reduced the coffee will not flow consistently out of the coffee dispenser...

Page 33: ...ing is too coarse and must be adjusted There is not enough coffee in the machine Adjust this with the aroma setting Coffee takes less than 15 seconds to make Adjust this with the aroma setting 12 9 Co...

Page 34: ...inding setting and the AromaControl Lighting defect Switch on the main switch Adjust the lighting Standby Press button Menu OK descale Descale the machine Fill up the water tank Fill up the water tank...

Page 35: ...sequence of numbers see chart on page 37 S1button Brewing unit operation anti clockwise Check that turning the brewing unit operation button anti clockwise functions correctly and also check the dispe...

Page 36: ...eck the turbine for correct functioning while water is flowing the display will show the details in l h under DX at the bottom S2 S7 buttons Solenoid valve function and steam Check the correct functio...

Page 37: ...6 Brewing unit switch Shows that the brewing unit is in place 7 Flap switch Shows that the flap is closed properly 8 Pump sensor Counts the pump impulses to determine the quantity of water for making...

Page 38: ...ler 1 Coffee 117 C Temperature high 110 C Previous coffee Temp normal 90 C Temperature measured in the boiler 1 Coffee 117 C Temperature high 110 C Temp rise 0 50 C Temp normal 90 C Temperature defini...

Reviews: