background image

4

GB

W A R N I N G

•  Venting  system  MUST  terminate  outside  the  home.
•  DO  NOT  terminate  the  ductwork  in  an  attic  or  other  enclosed  space.
•  DO  NOT  use  4"  laundry-type  wall  caps.
•  Flexible-type  ductwork  is  not  recommended.
•  DO  NOT  obstruct  the  flow  of  combustion  and  ventilation  air.
•  Failure  to  follow  venting  requirements  may  result  in  a  fire.

ELECTRICAL  REQUIREMENTS

A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-
delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance
with  the  electrical  rating  of  this  unit  as  specified  on  the  serial/rating  plate  located  inside  the  unit
near  the  field  wiring  compartment.  THIS  UNIT  MUST  BE  CONNECTED  WITH  COPPER  WIRE
ONLY. Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA
70  -  latest  edition,  and  all  local  codes  and  ordinances.  Wire  size  and  connections  must  conform
with  the  rating  of  the  appliance.  Copies  of  the  standard  listed  above  may  be  obtained  from:

National  Fire  Protection  Association
Batterymarch  Park
Quincy,  Massachusetts  02269

This  appliance  should  be  connected  directly  to  the  fused  disconnect  (or  circuit  breaker)  through
flexible,  armored  or  nonmetallic  sheathed  copper  cable.  Allow  some  slack  in  the  cable  so  the
appliance can be moved if servicing is ever necessary. A UL Listed, 1/2" conduit connector must
be  provided  at  each  end  of  the  power  supply  cable  (at  the  appliance  and  at  the  junction  box).

When making the electrical connection, cut a 1 1/4" hole in the wall. A hole cut through wood must
be  sanded  until  smooth.  A  hole  through  metal  must  have  a  grommet.

WARNING - TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with
any  solid-state  speed  control  device.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
OBSERVE THE  FOLLOWING:  Use  this  unit  only  in  the  manner  intended  by  the  manufacturer.  If
you  have  any  questions,  contact  the  manufacturer.

Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting
means  to  prevent  power  from  being  switched  on  accidentally.  When  the  service  disconnecting
means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service
panel.

CAUTION:  For  General  Ventilating  Use  Only.  Do  Not  Use  To  Exhaust  Hazardous  or  Explosive
Materials  and  Vapors.

WARNING - TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING: Installation Work And Electrical Wiring Must Be Done By Qualified
Person(s)  In  Accordance  With  All  Applicable  Codes  And  Standards,  Including  Fire-Rated
Construction.

Summary of Contents for KD 6500.1

Page 1: ...KD 6500 1 KD 9500 1 GB Instructions Booklet F Mode d emploi...

Page 2: ...2...

Page 3: ...his rangehood requires at least 24 of clearance between the bottom of the rangehood and the cooking surface or countertop This minimum clearance may be higher depending on local building code For exam...

Page 4: ...r nonmetallic sheathed copper cable Allow some slack in the cable so the appliance can be moved if servicing is ever necessary A UL Listed 1 2 conduit connector must be provided at each end of the pow...

Page 5: ...en cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors Electrical ground is required on this rangehood...

Page 6: ...lashback B optional Installation instructions For easy installation proceed as follows Fitting the wall brackets and Splashback Fixing the canopy Electrical connection and working test Ducting or Reci...

Page 7: ...correct height before fixing the base units or at least the worktop covering them As this is a complex operation it should only be undertaken by the technician installing the kitchen units or by a co...

Page 8: ...s until after the chimney has been installed Fitting the telescopic chimney To fit the upper section S first expand the two side pieces slightly hook them behind the brackets 2 and close them together...

Page 9: ...indicates automatically when it is time to carry out maintenance operations Metal grease filters Cleaning These filters must be washed when LED Filters starts or at the most once every 2 months using...

Page 10: ...charcoal filter saturation alarm ENABLED 1 flash of the LED Activated charcoal filter saturation alarm DISABLED Resetting the alarm signal To turn the alarm signal off proceed as follows Press the T4...

Page 11: ...MIT DE LA HOTTE DOIT TRE SCELL Gardez 24 po de hauteur entre le bas de la hotte et la surface de cuisson Cette hauteur minimum peut tre plus haute suivant le code municipal Par exemple les cuisini res...

Page 12: ...agit d un trou en bois sablez le bien tandis qu un trou passant par le m tal demande un bouche trou AVERTISSEMENT POUR R DUIRE LE RISQUE D INCENDIE OU DE CHOC ELECTRIQUE ne pas utiliser ce ventilateur...

Page 13: ...N utilisez pas un tuyau l eau froide pour la mise terre s il est branch un joint plastique non m tallique ou autre NE JOIGNEZ PAS la mise terre conduit de gaz N INSTALLEZ PAS un fusible dans le circui...

Page 14: ...vis chevilles et documents n 1 sole B option Instructions pour l installation Pour une installation ais e respecter le sch ma suivant Montage des triers de support et sole Montage du corps hotte Racco...

Page 15: ...monter la juste hauteur avant de monter les bases ou au moins le plan sup rieur correspondant Etant donn qu il s agit d une op ration compliqu e elle doit tre effectu e exclusivement par l installate...

Page 16: ...rieure I entre celle sup rieure S et la hotte C Chemin e avec grilles appliquer les grilles de direction cran sur la t le dans les si ges sp ciaux de mani re ce que le symbole soit orient vers le hau...

Page 17: ...moins jusqu au clignotement de confirmation des leds Dans tous les cas la signalisation d alarme saturation des filtres ne se v rifie que lorsque le moteur d aspiration est actionn ATTENTION il est n...

Page 18: ...ltres se saturent de graisses Eclairage Avant d essayer de remplacer les ampoules s assurer que l interrupteur soit hors circuit Il est constitu de 2 spots halog nes 20 W Mod le de 60 et de 3 spots ha...

Page 19: ...G G S I C B R P1 2 1 2 a b...

Page 20: ...S1 S1 1 1 1 1 1 1 R P1 T G S A18_714_03 R P1 T G S A18_714_03 G 2 S I 2 C 6 4 3 5 8 7...

Page 21: ...T1 T2 T3 T4 T5 9 10 11 12...

Page 22: ......

Page 23: ......

Page 24: ...01889 02 040210 K PPERSBUSCH Hausger te AG K ppersbuschstra e 16 D 45883 Gelsenkirchen Hausanschritt K ppersbuschstr 16 45883 Gelsenkirchen Telefon 02 09 4 01 0 Telefax 20 931 810 Telefax 02 09 4 01 3...

Reviews: