Special features of the EKE 6542.0
The EKE 6542.0 with four cooking zones has no menu key, so that all the functions are occupied by other
keys or combinations of keys.
The menu will be activated when the timer and the automatic boost function are pressed simultaneously
for five seconds.
An adjustment to a parameter can be acknowledged and stored with the automatic boost function key.
The 4-zone hob does not have the following menu settings:
-
F2
-
F3
-
F5
9.
Relay
The relay for universal switch-off (K101, K105, K111) are switched on at the same time when the hob is
switched on. These relays are switched off together when the hob is switched off.
The relays for the heating circuits are clocked in accordance with the power setting
Cooking zone cycle times (cycle time of 47seconds)
In order to prevent several relays from switching on or off at the same time, the relays are always
processed in internals of 90 ms. This maintains the switching procedure for the triple-circuit zones at
below 200 ms.
If the power setting is moved upwards when a cooking zone has been activated, the current cycle will
be disrupted for the respective zone and a new cycle will be started so that the heater is switched on
immediately.
If the power setting is moved downwards when a cooking zone has been activated, the remaining current
cycle of the heater will be switched off immediately for this particular cooking zone and the interval will
commence.
Setting
Switch-on time
1
1.3 seconds
2
3.5 seconds
3
5.7 seconds
4
8.7 seconds
5
11.2 seconds
6
14.0 seconds
7
21.2 seconds
8
28.2 seconds
9
47 seconds
Summary of Contents for EKE 6542.0
Page 21: ...H1 68 02 21 For internal use only 13 Wiring diagrams 13 1 EKE 6452 EKE 8452...
Page 22: ...22 H1 68 02 For internal use only 13 2 EKE 6452 EKE 8452 clamp connection schedule...
Page 23: ...H1 68 02 23 For internal use only 13 3 EKE 8752 EKE 8852...
Page 24: ...24 H1 68 02 For internal use only 13 4 EKE 6452 EKE 8452 clamp connection schedule...
Page 25: ...H1 68 02 25 For internal use only 13 5 EKE 8752 EKE 8852...
Page 26: ...26 H1 68 02 For internal use only 13 6 EKE 9852...
Page 27: ...27 H1 68 02 For internal use only 13 7 EKE 9852 clamp connection schedule...