XPS-E
32 / 36
7 FAQ
This section is treating the most frequent application problems and
their solutions.The most current questions and answers can be found
under
http://www.kunbus.de
DP-Master Status Message: Status 0xC2 (SAP/Service not
activated)
Make sure that the parametrization sequence of the parametrization
described in chapter „Parametrization“ [
}
9] has correctly been
executed. If necessary, repeat parametrization.
DP-Master Status Message: Status 0xC3 (no acknowledge)
Check the following points:
– Does the station address of the XPS-E correspond to the setting of the
PROFIBUS Master device?
– Are the bus parameters set correctly?
– Is the bus terminated correctly (switch position of the terminator
integrated in XPS-E)?
– Has XPS-E been connected correctly?
DP-Master Status Message: Status 0xC4 (bad telegram)
Check the terminating resistors at the bus. Pay attention to the switch
position of the terminating resistor at the XPS-E.
FAQ