- 7 -
RESISTANCE
RANGE RESOLUTION
ACCURACY
200Ω
0.1Ω
±(1.0% of rdg +10D)
2000Ω
1Ω
20KΩ
10Ω
200KΩ
100Ω
20MΩ
10KΩ
±(1.0% of rdg +10D)
200MΩ
100KΩ
±[5%*(rdg-10) + 10dgts)
±(1.0% of rdg +4D)
MAXIMUM OPEN CIRCUIT VOLTAGE: 3V.
OVERLOAD PROTECTION: 15 seconds maxi- mum
220Vrms.
TEMPERATURE (with K-TYPE PROBE)
RANGE
RESOLUTION ACCURACY
-40ºC~150ºC
±(1.0% + 4)
150ºC~1370ºC
±(1.5% + 15)
-40ºF~302ºF
±(1.0% + 4)
302ºF~1999ºF
±(1.5% + 15)
1ºC
1ºF
BATTERY TEST (DT33B only)
Range
Resol.
Internal Resistance
12V
10mV
1.2KΩ
9V
10mV
900Ω
1.5V
1mV
3KΩ
OPERATING INSTRUCTIONS
DC & AC VOLTAGE MEASUREMENT
1. Connect red test lead to “INPUT” jack, Black lead to
“COM” jack.
2. Set RANGE switch to desired VOLTAGE range, if the
voltage to be measured is not known beforehand, set
switch to the highest range and reduce it until
satisfactory reading is obtained.