The maximum loosening torque for [ Ind ] mode is 500 Nm.
① Turn the Reverse Lever to the left.
Reverse direction
( to loosen the right handed screw)
② Apply the reaction force absorber next to the fastening bolt/nut.
And press the throttle lever.
While loosening, [ - L - ] will be displayed.
If exceeding the maximum torque 500 Nm,
will be
displayed and the torque limiter will shut off the machine.
In this case, please use an impact wrench to loosen the bolt/nut.
・ While operating PTS, do not touch the reaction force absorber or the socket.
・ If something wrong with PTS, please release the throttle button and stop the
operation.
Warning
How to loosen ( 2 )
Industrial Mode [Ind]
Lights