7 Programming
Memory
Inputs
Outputs
Fig. 7-52: Function block KRC_Diag
Parameter
Type
Description
KRC_AxisGroup
RefArr
AXIS_GROUP_
REF_ARR
Reference to the internal structure of the axis group
Parameter
Type
Description
AxisGroupIdx
INT
Index of axis group
ShowTrace
BOOL
TRUE = activate display of the active function blocks in the
message window of the KUKA smartHMI.
FALSE = deactivate display of the active function blocks in
the message window of the KUKA smartHMI.
Note
: Only activate the display for test and diagnostic pur-
poses. If the display is active, approximate positioning is no
longer possible and the cycle time of the Submit interpreter is
adversely affected.
MaxSubmitCycle
INT
Maximum cycle time of the Submit interpreter
Default:
1,000 ms
Note
: If the maximum cycle time is exceeded, the
$MOVE_ENABLE signal for motion enable is reset.
Parameter
Type
Description
QueueCount
INT
Number of buffered statements
Heartbeat
INT
Heartbeat signal of the Submit interpreter (counter is incre-
mented by every Submit cycle)
1 … 245
SubmitCyc_Act
REAL
Current cycle time of the Submit interpreter; unit: ms
Mean value over 1,000 ms = 1/number of cycles per second
SubmitCyc_Min
REAL
Shortest cycle time of the Submit interpreter since the last
broken connection; unit: ms
SubmitCyc_Max
REAL
Longest cycle time of the Submit interpreter since the last
broken connection; unit: ms
SubmitCyc_Avg
INT
Mean value of the cycle time of the Submit interpreter during
the calculation period
Avg_Duration
; unit: ms