Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
KUKA.PLC mxAutomation Logix 1.0
412
INVALID CHECK-
SUM PLC -> KRC
The checksum for data transmission from the PLC to the robot
controller is invalid:
Error during start-up:
EtherNet/IP configuration in
WorkVisual or
RSLogix 5000 faulty
Check configuration in WorkVi-
sual and RSLogix 5000 and
configure EtherNet/IP correctly.
Error during operation:
Bit error during data transfer
Contact KUKA Roboter GmbH.
(
>>>
413
INVALID MOVE
TYPE
Internal exceptional error
Contact KUKA Roboter GmbH.
(
>>>
414
TIMEOUT HEART-
BEAT FROM PLC
Connection to PLC interrupted:
Restore connection, then
acknowledge error:
PLC program stopped
Restart the PLC program.
Submit interpreter deselected
or stopped
Restart Submit interpreter.
Connecting cable defective or
not correctly connected
Exchange connecting cable or
connect it correctly.
416
SYS VAR NOT INI-
TIALIZED
An error occurred when reading a system variable.
The specified system variable does not exist or may not be read in
the current operating state.
Example
: $POS_ACT cannot be accessed until a BCO run has
been carried out.
417
UNDERFLOW OF
NIBBLE
Internal exceptional error
Contact KUKA Roboter GmbH.
(
>>>
418
OVERFLOW OF
NIBBLE
Internal exceptional error
419
UNDERFLOW OF
BYTE
Internal exceptional error
420
OVERFLOW OF
BYTE
Internal exceptional error
421
UNDERFLOW OF
INT16
Internal exceptional error
422
OVERFLOW OF
INT16
Internal exceptional error
423
UNDERFLOW OF
INT32
Internal exceptional error
424
OVERFLOW OF
INT32
Internal exceptional error
425
UNDERFLOW OF
REAL
Internal exceptional error
426
OVERFLOW OF
REAL
Internal exceptional error
430
INVALID PTP APO
An invalid approximation
parameter has been transferred
for a PTP motion.
Program a valid value (parame-
ter
Approximate
).
(
>>>
431
INVALID CP APO
An invalid approximation
parameter has been transferred
for a CP motion (LIN, CIRC).
No.
Message text
Cause
Remedy