Issued: 13.08.2012 Version: KST PLC mxAutomation Logix 1.0 V1 en (PDF)
7 Programming
Memory
Inputs
Outputs
7.6.15
Reading an analog output
Description
The function block KRC_ReadAnalogOutput polls and reads an analog output
of the robot controller. This function is executed in the Submit interpreter.
Memory
Fig. 7-15: Function block KRC_ReadDigitalInput
Parameter
Type
Description
KRC_AxisGroup
RefArr
AXIS_GROUP_
REF_ARR
Reference to the internal structure of the axis group
Parameter
Type
Description
AxisGroupIdx
INT
Index of axis group
ExecuteCmd
BOOL
The statement is executed in the case of a ris-
ing edge of the signal.
Number
INT
Number of the analog input
1 … 32
Parameter
Type
Description
ErrorID
DINT
Error number
Done
BOOL
TRUE = statement has been executed
Value
REAL
Value of the analog input
Error
BOOL
TRUE = error in function block
Fig. 7-16: Function block KRC_ReadAnalogOutput
Parameter
Type
Description
KRC_AxisGroup
RefArr
AXIS_GROUP_
REF_ARR
Reference to the internal structure of the axis group