![Kuka KR C2 Operating Handbook Download Page 52](http://html.mh-extra.com/html/kuka/kr-c2/kr-c2_operating-handbook_2009633052.webp)
Machine Data
52 of 91
Maschinendaten 12.0400 en
2.1.105 $BRK_OPENTM
This machine datum may only be modified if it is absolutely certain that the
modification will not endanger persons.
Delay of command velocity output
Data type
int
min
Value
1
Unit
ms
Value
max ----
Assignment
----
Delay of command velocity output after the axis brakes have been opened (prevents motion
“against the brakes”).
Start
Open brakes
“Brake open”
Activate servos
Command value
$BRK_OPENTM
Signal processing time
Fig. 6
Delay
2.1.106 $BRK_DEL_COM
Time after which the axis brakes are closed on completion of positioning in the
command mode
Data type
int
min
Value
----
Unit
ms
Value
max ----
Assignment
----