![Kuka KR C2 Operating Handbook Download Page 40](http://html.mh-extra.com/html/kuka/kr-c2/kr-c2_operating-handbook_2009633040.webp)
Machine Data
40 of 91
Maschinendaten 12.0400 en
2.1.73 $ST_TOL_VEL[ ]
Velocity tolerance for standstill detection
Data type
real
min
Value
15.0
Unit
rpm
Value
max 15.0
Assignment
[1] axis 1 ... [6] axis 6
[7] external axis 1 ... [12] external axis 6
Velocity tolerance for standstill detection. This entry is fixed.
Default value = 15.0
+$ST_TO_VEL
--$ST_TO_VEL
t1 < $ST_TOL_TIME
t2 < $ST_TOL_TIME
Axis
stopped
t
v
Fig. 4
Standstill detection
2.1.74 $ST_TOL_TIME
Detection time
Data type
int
min
Value
15.0
Unit
ms
Value
max 15.0
Assignment
[1] axis 1 ... [6] axis 6
[7] external axis 1 ... [12] external axis 6
See Fig. 4.