Start-up
E 811 GB
20
27/02/2013
5 Start-up
Danger of damage to the unit!
If the device was exposed to condensation, allow it to rest for about 12 hours
before you start to use it.
5.1 TFT Monitor Calibration
5.1.1 Adjusting the Resolution
Mind that the Ventura Vico monitor must be attached to the controller PC be-
fore you switch on the power supply to the system. At the boot-up stage, the
monitor configuration stored by Ventura Vico is read by the controller PC's
BIOS and output to the graphics adapter board. This sets the operative reso-
lution and transfer parameters for this session.
There is no need for video framing correction as it would be normally per-
formed for a VGA interface.
In case the controller PC's BIOS does not support automatic download of the
monitor configuration, you can choose the "Control Panels / Monitor" func-
tion of your operating system to change the settings manually.
5.1.2 Adjusting the Brightness
There is a potentiometer at the back of Ventura Vico which you can use to
adapt the brightness of screen backlighting. To change the potentiometer
setting, put a screwdriver through the round hole in the cover over the inter-
face board.
Please use a flat-blade screwdriver max. 6 mm wide.
Brightness
- +