![KUHN Omnis 1000 Operator'S Manual Download Page 124](http://html1.mh-extra.com/html/kuhn/omnis-1000/omnis-1000_operators-manual_2009527124.webp)
Mounted field sprayers
122
OMNIS
Machine use
Machine rinsing
- Spray until pump unpriming.
- Place valves in incorporation circuit rinsing position:
• Suction valve: 1
• Rinsing tank valve (optional): 3
• Accessory valve: G
• Product incorporator lever (optional): D
• Discharge valve: A
- Engage the tractor PTO.
- Wait for 10 seconds.
- Place valves in tank rinsing position:
• Suction valve: 1
• Rinsing tank valve (optional): 3
• Accessory valve: F
• Product incorporator lever (optional): E
• Discharge valve: C
- Wait for 20 seconds.
The quantity of clear water added and/or the
number of tank rinse must be sufficient to
divide the tank bottom concentrate by at
least 100.
For models fitted with DPAE regulation (output
proportional to the groundspeed):
- Go to manual mode.
- Shut-off the flow regulation valve.
The tractor PTO stub must rotate at a speed of
250 min
-1
.