Mounted field sprayers
112
OMNIS
Machine use
Filling by suction:
- Open the manhole cover.
- Place valves in external suction position:
• Suction valve: 1
• Rinsing tank valve (optional): 4
• Accessory valve: G
• Product incorporator lever (optional): E
• Discharge valve: C
- Remove the quick coupler plug (1).
- Connect the hose to the quick coupler (1).
- Engage the tractor PTO.
- Fill the tank.
- Place the suction valve in position 2.
- Disengage tractor PTO.
- Disconnect hose from the quick coupler (1).
- Reinstall quick coupler plug (1).
- Close the cover.
For models fitted with DPAE regulation (output
proportional to the groundspeed):
- Go to manual mode.
- Open the flow regulation valve.