ORIGINAL OPERATING INSTRUCTIONS
Commissioning
11/15/2016
50/150
➯
3
Confirm
➯
4
Fill in spreading material into the spreader and put a reservoir that is
appropriately large under the screw conveyor outlet.
5
Hold down start button
➯
6
As soon as at least 300 impulses are reached, “OK” appears at the right
bottom corner of the monitor.
Now, the “START” button can be released.
For an exact setting, let out approx. 20 kg.
7
Now, weigh the collected spreading material and compare it with the
middle value (here: 20 kg).