Kübler Group
6 Maintenance
English
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 04
EN - 59
6 Maintenance
In harsh environments, we recommend regular inspections
for firm seating and possible damages at the device. Repair
work may only be carried out by the manufacturer, see
chapter Contact [
64].
Prior to the work
• Switch off the power supply and secure it against switching
on again.
• Then disconnect the power supply lines physically.
• Remove operating and auxiliary materials and remaining
processing materials from the measuring system.
6.1 Ex protection control and maintenance
DANGER
Explosion hazard due to thick dust layers
This dust layers lead to heat insulation and thus increase the
temperature at the surface of the device.
• Regularly check and clean the equipment in areas en-
dangered by the risk of dust explosion.
• Prevent dust accumulations on the encoder by a suitable in-
stallation.
• Clean the encoder regularly according to the application.
NOTICE
Damages at the encoder
Immediately replace the encoder in the event of damages,
especially at the seals.
6.2 Disassembly
NOTICE
Advice on "explosion protection"
When disassembling, take care not to damage the parts ne-
cessary for housing tightness. In no case re-use damaged
devices.
To dismount the device, proceed in the reverse order of the
assembly, see chapters Electrical Installation [
45].
6.2.1 Disassembling the Tapered Shaft
Unintentional seizing of the tapered shaft on the drive shaft
may require a tool to remove it.
6.3 Reassembly
Reassembling the device is only permitted under the follow-
ing conditions:
• The device is not damaged.
• The screws can be newly secured against loosening.
• All safety instructions of chapter Installation [
complied with.