![Kübler Sendix 58 FS2 Series Operation Manual Download Page 53](http://html1.mh-extra.com/html/kubler-0/sendix-58-fs2-series/sendix-58-fs2-series_operation-manual_2008446053.webp)
Kübler Group
4 Installation
English
BA Sendix® 58xxFS2 / 58xxFS3 - R60049.0009 - 04
EN - 53
0,1
Ra 1,6
ø
X
f6
(E
m
p
f.
ø
X
g
6
)
53088907
ATTENTION
Encoder damage
Device failure, device lifetime reduction.
• Comply with the minimum insertion depth of the drive in the
hollow shaft encoder.
For tapered shaft encoders
Material: Steel
0,02 A
1:10
A
Ra 1,6
2° 51´ 45´´ 0
-1-
ø
9
,2
5
7,5
±0,1
2
M
5
18014398562568459
4.1.4 Screw Retention
Secure the fastening screws against loosening. This is
achieved, depending on the application, using e.g.
• Coated screws
• Threadlocker
• Schorr washers
Kübler recommends a threadlocker, e.g. Loctite (order code:
8.0000.4G05.0000).
We recommend an additional protection against manipulation
by marking the fastening screws with locking varnish or sim-
ilar.