Oil/air cooler
Series OPC
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
43211 EN
4 of 20
5
Please observe protection
note ISO 16016.
Drawn:
2019-10-23 Pz/Str
Replacing:
KTR-N dated 2017-01-02
Verified:
2019-11-04 Pz
Replaced by:
Type OPC500 to 700
Illustration 2: OPC500 to 700
Table 2: Dimensions - Type OPC500 to 700
Type of cooler
Voltage
Current
[A]
Speed
[rpm]
l/min.
kW/°C
Dimensions [mm]
A
B
C
D
E
OPC500-16D-2.2kW
2
3
0
/4
0
0
V 5
0
Hz
4.9
1410
21.5
0.40
460
740
740
94
405
OPC500-25D-2.2kW
33.4
0.48
OPC500-32D-2.2kW
42.7
0.50
790
OPC500-40D-2.2kW
53.5
0.52
OPC600-16D-2.2kW
21.5
0.65
607
840
819
94
455
OPC600-25D-2.2kW
33.4
0.68
OPC600-32D-2.2kW
42.7
0.70
868
OPC600-40D-2.2kW
53.5
0.73
OPC700-40D-2.2kW
4.5
1435
56.0
0.77
608
990
973
530
Type of cooler
Dimensions [mm]
Weight
[kg]
F
G
H
I
J
K
L
M
N
OPC500-16D-2.2kW
150
157.5
657
130
720
30
330.0
547
G 1“
75
OPC500-25D-2.2kW
OPC500-32D-2.2kW
568
SAE
1 ½“
77
OPC500-40D-2.2kW
OPC600-16D-2.2kW
225
226.0
770
280
795
30
367.5
626
G 1“
96
OPC600-25D-2.2kW
OPC600-32D-2.2kW
647
SAE
1 ½“
98
OPC600-40D-2.2kW
OPC700-40D-2.2kW
920
732
130
1
Technical data