Oil/air cooler
Series OPC
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
43211 EN
5 of 20
5
Please observe protection
note ISO 16016.
Drawn:
2019-10-23 Pz/Str
Replacing:
KTR-N dated 2017-01-02
Verified:
2019-11-04 Pz
Replaced by:
Type OPC800 to 1000
Illustration 3: OPC800 to 1000
Table 3: Dimensions - Type OPC800 to 1000
Type of cooler
Voltage
Current
[A]
Speed
[rpm]
l/min.
kW/°C
Dimensions [mm]
A
B
C
D
E
OPC800-50D-4kW
4
0
0
/6
9
0
V 5
0
Hz
8.2
1460
69
1.00
701
981
1096
140
521
OPC800-80D-4kW
112
1.15
1130
OPC850-80D-5.5kW
12
970
72
1.12
870
1002
1046
95
523
OPC850-100D-5.5kW
113
1.32
1081
OPC850-125D-5.5kW
OPC900-80D-5.5kW
72
1.34
995
1312
1046
678
OPC900-100D-5.5kW
113
1.71
1081
OPC900-125D-5.5kW
OPC1000-125D-5.5kW
113
1.88
1119
113
OPC1000-180D-5.5kW
167
2.33
1136
Type of cooler
Dimensions [mm]
Weight
[kg]
F
G
H
I
J
K
L
M
N
OPC800-50D-4kW
350
340
920
280
670
20
292
829
SAE 2“
112
OPC800-80D-4kW
845
113
OPC850-80D-5.5kW
373
390
910
350
590
180
804
146
OPC850-100D-5.5kW
824
160
OPC850-125D-5.5kW
OPC900-80D-5.5kW
1182
440
615
210
804
SAE 3“
189
OPC900-100D-5.5kW
824
203
OPC900-125D-5.5kW
OPC1000-125D-5.5kW
844
217
OPC1000-180D-5.5kW
854
220
1
Technical data