12
- Insert wafers
with the number 1 into the chambers
,
and
.
- Insert the key and check whether the wafers with the
number 1
fi
t.
- Replace wafers that do not
fi
t with wafers with the right number.
NOTE
The wafers should be aligned
fl
ush with the locking cylinder. The
number of visible grooves indicates which wafer needs to be used.
This example shows a cylinder in which three wafers with
number
1
have been installed. Two grooves are visible on each of the two
protruding wafers. This means that wafers with
number 3
need to
be installed.
It is advisable to note down which numbers the matching wafers
have so that the other locking cylinders can be assembled in the
same manner.
- Repeat the steps for chambers
,
and
until the
fi
rst six
chambers are
fi
lled with the matching wafers.
- Insert spring
for the snap-in plate and then the snap-in plate
into chamber
.
NOTE
Chambers
and
remain empty.
- Mount O-ring
.
- Position locking cylinder as shown in the illustration and insert with
the aid of the key (catch must face upward).
Snap-in plate
engages.
ENGLISH