DC Power Interface
Interface
Screw-type terminal block
1. Two pairs for power wire cascading
2. One pair for power failure relay output
DC Jack (-D6.3mm/+D2.0mm)
Operating Input Voltages
+7V ~ +30V(+5%)
Power consumption
0.6W @+7.5VDC, 12VDC, 30VDC input
Basic Information
Conversion
RS-232 RX data to RS-485/422 TX data
RS-485/422 RX data to RS-232 TX data
Optical Isolation
Isolated between RS-232 and RS-485/422
3000VDC rms
Mechanical
Dimension (base)
W 28mm x D 82mm x H 95mm
Housing
Enclosed metal with no fan
Mounting Support
DIN-rail mounting, Panel mounting
Weight
240g
Environmental
Operating Temperature
-20
o
C ~ 70
o
C
Storage Temperature
-20
o
C ~ 85
o
C
Relative Humidity
5% ~ 90%