Quick installation and operating manual
KT-Elektronik
Manual mode
Switch to manual mode to configure all outputs, refer to wiring diagram
Select output depending on the control circuit:
POS1 :
Positioning value of valve M1
POS2 :
Positioning value pesp. voltage of analogue output
UP1:
Activation/deactivation of circulation pump UP1 (heating circuit)
ZP:
Activation/deactivation of circulation pump ZP
CP1:
Activation/deactivation of collector pump CP1
CP2:
Activation/deactivation of collector CP2
CU:
Activation/deactivation of collector valve CUV
SP1:
Activation/deactivation of storage tank pump SP1
SP2:
Activation/deactivation of storage tank pump SP2
NH:
Activation/deactivation of auxillary heating NH
SU:
Activation/deactivation of storage tank valve SUV
CTP:
Activation/deactivation of collektor / external heat exchanger pump CTP
TdS:
Activation/deactivation of temperature difference switch TdS
Set rotary switch to manual mode;
Display:
P0S I
Push rotary push button;
Display: Positioning value of valve M1
Turn rotary push button;
Edit positioning value of valve M1
Push rotary pushbutton;
Confirm positioning value of valve M1
Turn rotary pushbutton;
Display: further output
Return the rotary switch to normal position (information level).
The manual mode now is deactivated.
Display: Time
Note:
The outputs of the controller are not affected by simply turning the rotary switch to (manual level). You have to enter a
positioning value or activate/deactivate the pumps to configure the outputs.
The frost protection does not work during the controllers manual mode !