Quick installation and operating manual
KT-Elektronik
Information level
At the normal rotary switch position ,„Information level“, the time, date, public holidays and vacation periods as well as
the temperatures measured by the connected sensors and their set points ca be retrieved and displayed. (Press and hold
rotary push butten to display set points).
Depending on the configuration of the controller, the current values of the following data points are displayed one after the
other:
Set rotary switch to information level;
Display: time
__:__
Time
Outdoor temperature AF
Temperature at storage tank sensor
SF1
Room temperature RF
Temperature at storage tank sensor
SF2
Temperature at flow sensor of heating circuit VF
Temperature at collector sensor CF1
Temperature at flow sensor CVF
(collector to storage tank)
2
Temperature at collector sensor CF2
Temperature at return flow sensor CRF
(storage tank to collector)
Operating hours of solar circiut
Setting the controller time
Set rotary switch to time;
Symbol time and parameter blink,
Display: time
Turn rotary pushbutton;
Edit controller time
Push rotary pushbutton;
Confirm time; Display: year
Turn rotary push button;
Edit year
Push rotary pushbutton;
Confirm year; Display: date
Turn rotary pushbutton;
Edit Date
Push rotary pushbutton;
Edit date; Display: time
10
KA_37387_SOL3-7_EN004