3.
Place the shim (6) into the recesses for the foundation blocks (4) in accordance
with the general arrangement drawing.
4.
Align the pump with the piping.
5.
Place the foot (4) including the foundation blocks (1) with the adjusting screws
(5) on the shims (6). Use the adjusting screws to align the foot so that the
machined motor flange of the drive lantern is horizontal in both dimensions.
6.
Grout the holes for the foundation blocks with a quick-setting, low-shrinkage
concrete mixture.
7)
7.
When the concrete has set, tighten the foundation bolts (2) evenly.
8.
Connect the piping to the pump without transmitting any stresses or strains.
(
⇨
Section 5.4 Page 30)
9.
Mount the motor on the drive lantern as described in the motor manufacturer's
operating instructions.
10. Align the coupling as described in the coupling manufacturer's operating
instructions.
5.3.5
Type of installation DP
DANGER
The pump or individual components could slip out of the suspension arrangement
Danger to life from falling parts!
▷
Always transport the pump or components in the specified position.
▷
Never attach the suspension arrangement to the free shaft end of the pump.
▷
Refer to the weights indicated for the individual components.
▷
Observe the applicable local health and safety regulations.
▷
Use suitable, permitted lifting accessories.
Fig. 10: Pump on foot (baseplate), drive on support frame
✓
The relevant general arrangement drawing is available.
✓
The foundation has the required strength and characteristics.
✓
The foundation has been prepared in accordance with the dimensions given in
the outline drawing.
7)
Minimum strength class C25/30
5 Installation at Site
28 of 94
Omega / Omega V
Summary of Contents for Omega
Page 93: ......