5 Installation at Site
29 of 72
HPK
WARNING
Failure to use or incorrect use of auxiliary connections (e.g. barrier fluid, flushing
liquid, etc.)
Risk of injury from escaping fluid!
Risk of burns!
Malfunction of the pump!
▷
Refer to the general arrangement drawing, the piping layout and pump
markings (if any) for the quantity, dimensions and locations of auxiliary
connections.
▷
Use the auxiliary connections provided.
5.5 Enclosure/insulation
DANGER
Risk of potentially explosive atmosphere due to insufficient venting
Explosion hazard!
▷
Make sure the space between the casing cover/discharge cover and the bearing
cover is sufficiently vented.
▷
Never close or cover the perforation of the bearing bracket guards (e.g. by
insulation).
WARNING
The volute casing and casing/discharge cover take on the same temperature as
the fluid handled
Risk of burns!
▷
Insulate the volute casing.
▷
Fit protective equipment.
CAUTION
Heat build-up in the bearing bracket
Damage to the bearing!
▷
Never insulate the bearing bracket, bearing bracket lantern and casing cover.
5.6 Checking the coupling alignment
DANGER
Inadmissible temperatures at the coupling or bearings due to misalignment of the
coupling
Explosion hazard!
Risk of burns!
▷
Make sure that the coupling is correctly aligned at all times.
Summary of Contents for HPK
Page 71: ......