5 Installation at Site
19 of 32
AmaSlide
2553.870/01-EN
Size
(d
1
× l
1
)
d
2
t
1
t
2
SW
1
3)
SW
2
3)
M
d1
[mm]
[Nm]
M24 × 300
4)
28
65
210
36
17
180
M30 × 380
4)
35
65
280
46
-
400
Table 7:
Curing times of mortar cartridge
Floor temperature
Curing time
[°C]
[min]
-5 to 0
240
0 to +10
45
+10 to +20
20
> +20
10
81-30
904.01
904.01
904.01
904.01
Fig. 10:
Positioning the guide rails / Fitting the chemical anchors
15. Position guide rails 81-30.
16. After the curing time specified in the "Curing times of mortar cartridge" table,
tighten the nuts of the four chemical anchors 904.01 evenly.
183
901.65/550.65
901.65/550.65
901.26
Fig. 11:
Fitting the support foot
17. Tighten hexagon head bolts 901.65/550.65 at support foot 183.
18. Tighten hexagon head bolt 901.26 at the motor cover.
3)
SW = Width across flats