5 Installation at Site
18 of 32
AmaSlide
2553.870/01-EN
81-30
904.01
904.01
904.01
904.01
183
Fig. 8:
Preparing guide rail installation (
Section 8.2, Page 27) / chemical anchors
9. Position guide rails 81-30 underneath the motor such that they run parallel to
the (pump-end/motor-end) adapters / parallel to the motor centreline and align
with support foot 183.
10. Mark the four fastening points for chemical anchors 904.01.
11. Remove guide rails 81-30 again.
12. Drill four holes for chemical anchors 904.01 in accordance with the "Chemical
anchor dimensions" table. Then clean the holes.
WARNING
Improper handling of mortar cartridge
Skin sensitisation and/or irritation!
▷
Wear suitable protective clothing.
13. Insert the mortar cartridges into the four holes drilled for chemical anchors
904.01. Observe the curing times of the mortar cartridges!
14. Drive threaded rods into the four holes drilled for chemical anchors 904.01 using
an impact drill or hammer drill.
Chemical anchor
dimensions
t
2
t
1
SW
1
d
1
SW
2
d
2
l
1
Fig. 9:
Dimensions
Table 6:
Chemical anchor dimensions
Size
(d
1
× l
1
)
d
2
t
1
t
2
SW
1
3)
SW
2
3)
M
d1
[mm]
[Nm]
M10 × 130
12
22
90
17
6
20
M12 × 160
14
25
110
19
8
40
M16 × 190
18
35
125
24
12
60
M20 × 260
25
65
170
30
14
120