6 Commissioning/Start-up/Shutdown
29 of 60
Ama-Drainer 4../5..
Table 8:
Particle size for slightly contaminated waste water
Type series
Max. particle size
[mm]
Ama-Drainer /10
10
Ama-Drainer /11
11
Ama-Drainer /35
35
6.3 Shutdown/storage/preservation
6.3.1 Measures to be taken for shutdown
WARNING
Unintentional starting of the pump set
Risk of injury by moving components and shock currents!
▷
Ensure that the pump set cannot be started unintentionally.
▷
Always make sure the electrical connections are disconnected before carrying
out work on the pump set.
WARNING
Fluids handled, consumables and supplies which are hot and/or pose a health
hazard
Risk of injury!
▷
Observe all relevant laws.
▷
When draining the fluid take appropriate measures to protect persons and the
environment.
▷
Decontaminate pumps which handle fluids posing a health hazard.
1. Disconnect the pump from the power supply and protect it against start-up.
2. Wait until the pump has cooled down (10 minutes), then remove it.
3. Properly flush the pump.
Point the water jet on the pump's discharge nozzle.
4. Leave the pump to dry.
5. Store the pump vertically in a dark, dry and frost-proof room.
6.4 Returning to service
For returning the pump to service observe the sections on commissioning/start-up
and the operating limits.
In addition, carry out all servicing/maintenance operations before returning the
pump (set) to service.
NOTE
On pumps/pump sets older than 5 years we recommend replacing all elastomer
seals.